Specification: |
|
100mV Input: |
|
|
External Connector |
2 pin Switchcraft Plug (EN3C2M
) |
Weatherproof |
IP66 |
|
|
|
Pinout |
 |
View from Front of Socket or Rear of Plug |
|
|
|
Maximum readable input voltage |
110 mV |
|
|
Maximum voltage input without damaging logger |
10 Volts |
|
|
Input Leakage Current |
1nA |
|
|
|
|
|
|
If the logger is connected to a
computer and either input is held at mains earth potential, erroneous results can be
expected due to the earth loop current. |
|
|
|
|
Internal Temperature: |
|
|
Sensor Type |
Thermister |
|
|
Linear accuracy over range |
± 0.3º C (0º C to 70º C) |
|
|
Repeatability |
± 0.1º C |
|
|
Long term stability |
± 0.1º C |
|
|
|
|
|
Logger: |
|
|
Working Temperature |
-30º C to +70º C |
|
|
Storage Temperature |
-30º C to +70º C |
|
|
Sampling Rate |
1 second minimum |
10 hours maxium |
in 1 second intervals |
|
|
|
Storage capacity |
64,000 8 bit samples |
32,000 12bit samples |
|
|
|
Alarms |
Two independent Alarms |
Triggered on any combination of six user configurable
Alarm Conditions |
One alarm can be configured to dial a PocketPager |
Alarms can be visually checked using the Omnilog Software |
|
|
|
Start modes |
Start immediately |
Start on date/time. |
|
|
|
Stop modes |
Stop when memory is full |
Stop on date/time |
Loop around (continues logging) |
|
|
|
Logging Modes |
Each channel can be set to log any combination of: |
- Point readings
- Average reading
- Maximum reading
- Minimum reading
|
|
|
|
Battery |
Factory Replaceable |
One ½ AA 3.6V lithium cell |
Five year life. |
The data is retained in the case of battery failure. |
Battery Status Monitor in OmniLog Software |
|
|
|
Download Time |
35 seconds for Full Logger |
|
|
Case material |
304 Stainless tube |
|
|
Screw on end cap |
Plated brass |
|
|
Weight |
110g |
|
|
Size |
20mm diameter X 168mm long |